When taking a break
Stop the machine during breaks.
During all breaks you must put the machine away
so that there is no risk for unintentional start.
Maintenance
Regular maintenance is a basic requirement for the
continued safe and efficient use of the machine.
Follow the maintenance instructions carefully.
Before starting maintenance on the machine, clean
it in order to avoid exposure to hazardous
substances. See “Dust and fume hazards”
Use only authorised parts. Any damage or
malfunction caused by the use of unauthorised
parts is not covered by warranty or product liability.
When cleaning mechanical parts with solvent,
comply with appropriate health and safety
regulations and ensure there is satisfactory
ventilation.
For major service to the machine, contact your
nearest authorised workshop.
After each service, check that the machine's
vibration level is normal. If not, contact your
nearest authorised workshop.
Every day
Before undertaking any maintenance or changing
the inserted tool, turn the machine off.
Clean and inspect the machine and its functions
each day before the work commences.
Perform a general inspection and check that there
are no leaks and no damage.
Check the electrical cabels and electrical
insulations for wear, change if necessary.
Check that the O-ring on the oil plug is undamaged
and seals properly.
Check that the oil plug is tightened regularly.
Check the insertion tool, make sure that it is sharp
and not worn out.
Change damaged parts immediately.
Replace worn components in good time.
In order to ensure that the machine remains within
the stated vibration level values, the following checks
must be performed:
Every year
Overhauling must be done after one year of
continuous operation. Overhauling must for safety
reasons be performed by authorised personnel at an
authorised workshop.
Repair
Replacing the starter cord
WARNING Spring tension
The starter spring may cause personal injury by
striking the operator or other persons.
Wear impact resistant eye protection with side
protection and gloves.
Removing the old starter cord
1. Remove the screw-cap of the PTO and the three
bolts from the protective cover of the starting
mechanism.
2. Lift off the cover, grasping the starter pulley as
well. Let the cover rotate carefully against the
starter pulley, to release the spring tension.
3. Remove the old starter cord.