Part 6 Gas Conversion
Pilot Burners
1. Disconnect pilot supply and thermocouple tubes
from the gas control valve.
2. Undo the 2 screws securing the pilot assembly to
the griddle toaster main frame.
3. Withdraw the pilot assembly, remove the existing
pilot injectors and replace with the correct size
injectors.
4. Repeat for the second pilot burner.
5. Re-assemble the pilot burners to the griddle
toaster.
6. Refit the main control panel.
Low Fire Adjustment
1. Set the burner low fire adjustment. The low fire
screw on the gas control valve should be
screwed fully 'In', then unscrewed by the
measurement shown in the “Gas Specifications”
table at the end of this section.
NOTE:
The “Low Fire Adjustment Screw” should be sealed
with coloured paint on completion of the low fire
adjustment.
2. Refit the front control panel and secure in
position by tightening the 2 screws on the front
lower edges of the control panel.
3. Refit the gas control knobs to the gas control
valves. The gas control knobs are a push fit onto
the shaft of the gas control valves.
Gas Conversion Procedure
NOTE:
 These conversions should only be carried out
by qualified service persons. All connections
must be checked for leaks before re-
commissioning the appliance.
 For all relevant gas specifications refer to the
table at the end of this section.
Main Burners
1. Ensure that the gas supply has been turned 'Off'.
2. Remove control panel and toasting rack.
3. Unscrew the wing nut at the rear of burner and
lift out the burner.
4. Determine correct injector sizes for the
corresponding gas from the table shown in the
'Gas Specifications' section.
5. Remove the injectors from the injector support
bracket.
6. Replace with the correct size injectors.
7. Repeat for the second main burner.
8. Refit the main burners to the griddle toaster.
C
AUTION
:
Ensure that the unit is isolated from the gas
supply before commencing servicing.
Wing Nut
Main Burner Injector
Thermocouple
Connection
Pilot Securing Screws
Pilot Gas Supply Tube
Low Fire Adjustment Screw
Page view 11